| MI 3125 BT | MI 3100 SE | MI 3152 | MI 3155 |
Screen type | | | | |
Monochrome dot matrix | | | | |
Full colour dot matrix | | | | |
Touch screen | | | | |
Instrument control | | | | |
Rotary switch | | | | |
Push keys | | | | |
Functions | | | | |
3-wire Trip-Lock RCD function, with no reported RCD uplift | | | | |
Hi current loop test for L-L and L-N testing and where there is no RCD | | | | |
PFC and PSCC displayed with loop impedance | | | | |
Operating frequency | 45Hz to 65Hz | 45Hz to 65Hz | 45Hz to 65Hz | 14Hz to 500 Hz |
Earth loop impedance ranges | | | | |
3-wire loop test | | | | |
Fuse tables on-board for instant pass or fail | | | | |
Z auto func., Ze, Zs, PFC, PSCC and touch voltage with the single press of test button | | | | |
Ultra-low current test for vehicle charge point testing | | | | |
Supports Hi resolution testing with A 1143 adapter | | | | |
4-wire loop test for result close to the source of supply | | | | |
50V, 100 V, 250 V, 500 V and 1 kV test voltages | | | | |
2.5 kV test voltage | | | | |
Applied voltage display | | | | |
Insulation test ranges | | | | |
Pass of fail against pre-set limits | | | | |
AUTO L-PE, N-PE and L-N testing | | | | |
Surge protection or varistor testing | | | | |
Diagnostic tests PI and DAR | | | | |
AC RCD rating 10 mA, 30 mA, 100 mA, 300 mA, 500 mA and 1000 mA | | | | |
RCD Type A, Type AC, Type F | | | | |
RCD Type B and Type B+ - pure DC | | | | |
Standard or time delayed | | | | |
RCD testing ranges | | | | |
Portable RCDs type PRCD, PRCD-2P, PRCD-3P, PRCD- S, PRCD- S+ & PRCD- K | | | | |
EV RCM / EV RCD 30 mA AC and 6 mA DC* | | | | |
Phase or polarity | 0 / 180 | 0 / 180 | 0 / 180 | 0 / 180 |
½I, I and 5I tests | | | | |
Ramp test for RCD fault finding | | | | |
Continuity and low R range | | | | |
Auto RCD test for trip time and trip current displayed on a single screen, no scrolling | | | | |
7 mA test current for continuity check through RCD & prolonged battery life | | | | |
Adjustable Pass/ fail indicator light limits | | | | |
Adjustable buzzer threshold | | | | |
AUTO SEQUENCE | | | | |
Pre programmed | | | | |
User programmable | | | | |
Testing TN and TT earthing systems | | | | |
Testing IT, floating earth systems | | | | |
Voltage, frequency and phase rotation range | | | | |
0 V to 550 V AC resolution 1V | | | | |
Single-phase TN/ TT systems displays L-N, L-PE , N-PE in single screen | | | | |
3-phase TN/ TT systems displays L1-L2, L1-L3 , L2-L3 in single screen | | | | |
True RMS measurement | | | | |
Frequency | 0Hz to 500 Hz | 0Hz to 500 Hz | 0Hz to 500 Hz | 0Hz to 500 Hz |
Phase rotation | | | | |
Voltage Drop measurement | | | | |
Power quality range | | | | |
Active power (P), Apparent power (S) and Reactive power (Q) | | | | |
Power factor, Total harmonic distortion (THD) | | | | |
Voltage harmonics and THD | | | | |
Current harmonics and THD | | | | |
Earth electrode resistance range | | | | |
3-wire technique | | | | |
Selective method with 3-wires and clamp* | | | | |
4-wire earth resistivity* | | | | |
2 clamps contactless method* | | | | |
Earth test set supplied | | | | |
Active safety system | | | | |
Auto-test inhibit | | | | |
Auto- discharge | | | | |
Auto PE test | | | | |
Touch voltage monitoring | | | | |
Results handling / on-board memory | | | | |
On-board memory size | 3 levels / 1700 locations | 3 levels / 1700 locations | 8 GB | 8 GB |
Memory management | | | | |
Workspace manager | | | | |
Full keyboard for labelling files and results in plain English | | | | |
USB, RS232 and bluetooth® connectivity | | Optional accessory | | |
QR and, or barcode scanner support* | | | | |
FREE Electrical Safety Management Basic software license | | | | |
Other benefits | | | | |
Rechargeable batteries with on-board recharging | | | | |
TRMS leakage and load measurement* | | | | |
Illuminance measurement* | | | | |
Cable tracing* | | | | |
Insulation monitoring device testing - IT systems | | | | |
First fault leakage current measurement - IT systems | | | | |
Records visual inspection | | | | |
Full set of test, download and recharge leads | | | | |
Soft test and carry bag | | | | |
Firmware user updatable for product’s lifetime | | | | |
Safety rating | CAT IV 300 V | CAT IV 300 V | CAT IV 300 V | CAT IV 300 V |