• approved distributor

    Buy or Hire Test Equipment
    Repair | Calibrate | Training

  • product advice and demos

    Product advice & demos
    Aftersales support

  • competetive prices

    Competitive quotes
    Bespoke deals

  • approved distributor

    Approved distributor
    Approved service centre

 

Be the first to review this product
0
(0)

Fluke
ii910 Precision Acoustic Imager


FLUKE ii910 Precision Acoustic Imager designed to detect partial discharge in high voltage applications & detect leaks in compressed air, gas, steam & vacuum systems. With increased detection & frequency range this really is an impressive bit of kit!

Part Number:
FLK-II910

read more

 

Need Help ? Contact Us Request Demo Browse Accessories
Acutest's Price Promise
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

Manufacturer's RRP

£21628.00
25953.60 incl. VAT)
Add To Cart
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

 

 

FLUKE ii910 Precision Acoustic Imager

Discover the simple way to quickly detect, locate & analyse partial discharge (PD) with confidence.

Partial discharge is a very serious issue and often difficult to find. Whether you are inspecting insulators, transformers, switchgear or high voltage powerlines you need to be confident you can spot a problem in time to fix it long before it becomes catastrophic. Partial discharge that goes unchecked can cause blackouts, fires, explosions, or deadly arc flashes. There is a significant monetary risk of downtime.

 

What is different about the FLUKE ii910?

Compared to the FLUKE ii900

Frequency Range:

  • ii900: From 2 kHz to 52 kHz
  • ii910: From 2 kHz to 100 kHz

Detection Range:

  • ii900: Up to 70 meters (230 feet)*
  • ii910: Up to 120 meters (393 feet)*

*Depending on ambient conditions

The FLUKE ii900 Series enables you to detect leaks in compressed air, gas, steam and vacuum systems hurt both production uptime and the operations bottom line.

Knowing these leaks exist isn‘t new... but an efficient way to detect them is!  Minimal training is required so your maintenance technicians can begin checking for leaks during their typical maintenance routine, even during peak hours of operation.

The ii900 series acoustic imagers let technicians see sound as they scan hoses, fittings, and connections for leaks. Its built-in acoustic array of tiny sensitive microphones generates a spectrum of decibel levels per frequency. Based on this output, an algorithm calculates a sound image, known as SoundMap that is superimposed on a visual image. The SoundMap is automatically adapted depending on the frequency level selected so that background noise is filtered out, making it incredibly simple to detect compressed gas leaks.

The FLUKE ii910 provides increased sensitivity to detect leaks that are smaller or farther away.

 

▶ Video: What‘s The Difference FLUKE ii900 & ii910?:

Video thumbnail for the FLUKE ii900 & ii910 Difference

 

FLUKE ii910 Partial Discharge Detection

The invisible threat…now you can see

Partial Discharge (PD Detection) is a very serious issue - To monitor quickly and easily is important.

Whether you are inspecting insulators, transformers, switchgears or high voltage powerlines you need to be sure that you spot a problem quickly and early.

Partial discharge that goes unchecked can cause blackouts, fires, explosions, or death from arc flashes. In addition to the danger that partial discharge poses to human lives and the environment, there is a significant monetary risk of downtime. Having equipment go down can cost millions of dollars per hour of downtime.

The FLUKE ii910 Precision Acoustic Imager is the perfect tool for high voltage electricians, electrical test engineers, and grid maintenance teams that are constantly inspecting and maintaining power distribution and industrial high voltage equipment. The ii910 provides a safe quick and easy way to detect and locate partial discharge in order to maintain high voltage equipment and prevent catastrophic events. With the SoundSight technology the ii910 translates the sounds that it hears into a visual representation so that you can quickly locate problem areas. The higher frequency capability of the ii910 allows for earlier detection to facilitate early maintenance planning and is why the ii910 has a frequency range of 2-100Khz.

 

▶ Video: Detecting Partial Discharge with the FLUKE ii910?:

Video thumbnail for the FLUKE ii910 and PD Detection

 

FLUKE ii910 Applications:

  • Detect partial discharge early allowing for proper scheduling of maintenance, increasing uptime
  • Quickly and easily scan areas to find potential problems
  • Detect and analyse partial discharge from a safe distance
  • Cut costs and save energy everyday by taking the guesswork out of finding and fixing partial discharge
  • Plus detect leaks in compressed air, gas, steam and vacuum systems

To read more about the full list of features from the FLUKE ii900 series.

 

▶ Video: How can the FLUKE ii910 Benefit You?:

Video thumbnail for the FLUKE ii910 Benefits

 

 

▶ Video: FLUKE ii910 Precision Acoustic Imager‘s MecQ Mode (Conveyor System Application)

Video thumbnail for the FLUKE ii910 Precision Acoustic Imager‘s MecQ Mode

 

What comes with the FLUKE ii910?

  • FLUKE ii910 Sonic Industrial Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap

 

Comparison Chart for: Fluke ii910 Precision Acoustic Imager

ii900ii910
Sensors
Frequency band2 kHz to 52 kHz2 kHz to 100 kHz
Detection range (*Depending on ambient conditions)0.5 to > 70 meters (1.6 to > 230 feet)*0.5 m to 120 m (1.6 to 393 feet)*
Measurement range
15.4 dB SPL to 115.2 dB SPL12.1 dB SPL to 114.6 dB SPL
±1 dB SPL 2 kHz±1 dB SPL 2 kHz
5.6 dB SPL to 102.5 dB SPL4.4 dB SPL to 101.2 dB SPL
±2 dB SPL 19 kHz±2 dB SPL 19 kHz
28.4 dB SPL to 131.1 dB SPL12.8 dB SPL to 119.2 dB SPL
±1 dB SPL 35 kHz±1 dB SPL 35 kHz
41.8 dB SPL to 133.1 dB SPL19.8 dB SPL to 116.1 dB SPL
±3 dB SPL 52 kHz±3 dB SPL 52 kHz
41.4 dB SPL to 129.0 dB SPL
±1 dB SPL 80 kHz
54.4 dB SPL to 135.5 dB SPL
±1 dB SPL 100 kHz
Classification and quantificationLeakQ™ Leak size and cost estimationLeakQ™, MecQ™, and PDQ Mode™ Leak size and cost estimation / Mechanical inspection / Partial discharge type classification
FLUKE ii900 SERIES FEATURES
Both ii900 and ii910Both ii900 and ii910 - See Previous Column
# of microphones64 digital MEMS microphones
Field of View63 ° ± 5 °
Minimum Frame Rate12.5 FPS
Built-in digital camera (visible light)
Field of View (FOV)63 ° ± 5 °
FocusFixed lens
Display
General7" LCD with backlight (under-sunlight readable)
Resolution1280 x 800 (1,024,000 pixels)
TouchscreenCapacitive
Acoustic Image (SoundMap image)
Image storage
Storage capacityInternal memory with the capacity for 999 picture files or 20 video files
Image formatBlended visual and SoundMap .JPG or .PNG
Video formatBlended visual and SoundMap .MP4
Video length30 seconds
Digital exportUSB-C for data transfer
Acoustic Measurements
Auto max/min dB gainAuto or manual (user selectable)
Frequency band selectionUser selectable through user-made presets or manual entry
Software
Ease of useIntuitive user interface
Trend graphsFrequency and dB scale
Spot markersdB level reading at center point of the image
Battery
Batteries (rechargeable field-replaceable)Rechargeable Li-ion (Fluke BP291)
Battery life6 hours (product includes spare battery)
Battery charging time3 hours
Battery charging systemExternal dual-bay charger (EDBC 290)
General Specifications
Standard palettes3: Grayscale / Ironbow / Blue-Red
Operating Temperature0 °C to 35 °C (32 °F to 95 °F)
Storage Temperature-20 °C to 70 °C (-4 °F to 158 °F)
Relative humidity10 % to 95 % non-condensing
Size (H x W x L)186 mm x 322 mm x 68 mm
Weight (battery included)1.7 kg (3.75 pounds)
Main unit ratingIP40 protection against particles 1mm or greater and dripping water
Sensor head ratingIP51
Warranty2 year
Self-diagnostic notificationArray-health test to identify when microphone array needs attention
RoHS compliant
Safety
General SafetyIEC 61010-1
Electromagnetic Compatibility (EMC) InternationalIEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1 (Class A)

 

Accessory Code Description Price (Ex VAT)
BP291 4800 mAh High Capacity Li-Ion Battery £433.00 ADD

 

 

ONLY REGISTERED USERS CAN WRITE REVIEWS. PLEASE SIGN IN OR CREATE AN ACCOUNT

Last working day:
Tuesday 24th Dec
(offices close from midday)

Reopening:
Thursday 2nd Jan

Festive Wishes!

Christmas Shutdown