NEW Megger MFT-X1 Multifunction Tester

New Megger Multifunction Tester MFT-X1 Specifications and Videos

The NEW Megger MFT-X1 Multifunction Tester has now been launched!

This user-upgradeable MFT incorporates a host of new features based on years of customer input.

The MFT-X1 offers True Loop (Megger's industry leading loop impedance test with patented Confidence Meter technology), full CertSuite compatibility to streamline certificate creation; plus high resolution loop testing, stabilised insulation voltage output and a full colour screen and... new operator interface!

The user upgradeable operating software ensures the MFT-X1 has the ability to adapt to regulation changes, making it the perfect instrument for fast, reliable, accurate and adaptable testing!



▶ Video: MFT-X1 Easy Battery Change

 

▶ Video: MFT-X1 Demonstration - Electrical Testing Application

 

▶ Video: MFT-X1 Demonstration - EVSE Testing Application



Megger MFT-X1 Specification:

Voltage Measurement  
Voltage range 0.001 V to 2 V (mV range) 2 V to 600 V (V range), 1000 V DC (on-CAT rated circuits)
Voltage type: Trms, AC, DC
Phase sequence Automatic phase sequence testing on detection of valid three phase supplies
Current Measurement (Non-Contact)  
AC Trms Using optional accessories: MCC1010 current clamp
Measurement Range MCC1010: 1 mA to 300 A
Continuity/Resistance  
Measurement range Digital display 0.01 Ω to 999 kΩ Auto-ranging
Measurement Range Analogue arc 0 Ω to 1 MΩ log scale
Test voltage 4 V DC to 5 V DC
Test current (Nominal) >200 mA 0 Ω >< 2 Ω
  10 mA
  Auto reduction on high resistance (actual current reported in display)
Test polarities Forward polarity
Buzzer resistance range > 0.01 Ω < 2 kΩ
Buzzer threshold 0.3, 0.5, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 100, 200 Ω
Insulation Testing  
Measurement range Digital display 0.001 MΩ to 999 MΩ Auto-ranging
Measurement range Analogue arc 0.001 MΩ to >1000 MΩ log scale
Insulation test voltages 50 V DC to 1000 V DC + Variable 50 V to 999 V
Test current 1 mA to 2 mA
Stabilised output voltage Output test voltage stabilised to -0% +2% +2 V
Loop Impedance Testing  
2 Wire - all modes  
Test types Mode 1: Non-Trip
  Mode 2: High current
  Mode 3: High resolution
Resolution Non-Trip: 0.01 Ω
  High current: 0.01 Ω
  High resolution: 0.001 Ω
Voltage range Non-trip: 48 V AC to 280 V AC
  High current: 48 V AC to 550V AC
  High resolution: 48 V AC to 550 V AC
Frequency range 45 Hz to 65 Hz (all modes)
Phases Non-trip: Single phase
  High current: Three phase
  High resolution: Three phase
3 wire - non-trip  
Test types RCD (non-trip) RCD EV (non-trip on 6mA EV RDCs)
Resolution 0.01 Ω
Voltage range 48 V AC to 280 V
Frequency range 45 Hz to 65 Hz
Phases Single phase
Volt drop  
Volt drop calculation Requires Zref (Ze) and circuit current (I-vdrop)
Accuracy Dependent on loop impedance accuracy
RCD Testing  
RCD types supported Type AC, A, B, AC(S), A(S), B(S)
Auto RCD sequence 1/2x I∆n, 1x I∆n, 2x I∆n, 5x I∆n, Ramp, 0º/180º (customer configurable)
Ramp testing 10 mA to 1000 mA
RDC testing 6 mA RDC
Fault (Touch) voltage 0 V to 253 V
Earth testing  
2 wire 2 wire earth resistance test



Watch the Megger MFT-X1 Introduction:

Watch to learn more about the NEW Megger MFT Display:

VIEW MEGGER MFT-X1 DATA SHEET

VIEW MORE MEGGER MFT-X1 INFO